{"id":59,"date":"2021-03-08T00:00:38","date_gmt":"2021-03-08T00:00:38","guid":{"rendered":"http:\/\/durasens.com\/?page_id=59"},"modified":"2021-03-08T14:40:35","modified_gmt":"2021-03-08T14:40:35","slug":"liquid-cells","status":"publish","type":"page","link":"https:\/\/durasens.com\/index.php\/liquid-cells\/","title":{"rendered":"Liquid Cells"},"content":{"rendered":"\n<p>Our broad range of robust liquid flow cells are equally at home in the laboratory, pilot plant or manufacturing plant. Constructed in a variety of materials such as various grades of stainless steel or Hastelloy, the cells can be customized depending on the spectral range and application. A variety of seals and any standard industrial flow fittings can be selected, Transmission cells are available in a variety of pathlenths. All our cells can be equipped with a temperature control version.<\/p>\n\n\n\n<p>Please <a href=\"http:\/\/durasens.com\/contact_us\" target=\"_blank\" rel=\"noreferrer noopener\">contact us<\/a> regarding your specific application.<\/p>\n\n\n\n<h4 class=\"has-accent-color has-text-color wp-block-heading\"><span style=\"color:#e15814\" class=\"has-inline-color\">LT-B Series<br>Basic Liquid Transmission Flow Cells<br>Models LT-B13, LT-B25, LT-B13-T, LT-B25-T&nbsp;<\/span><strong>&nbsp;<\/strong><\/h4>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-2 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-1 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"178\" height=\"235\" src=\"https:\/\/durasens.com\/wp-content\/uploads\/2021\/03\/LT-B-web-2.jpg\" alt=\"\" class=\"wp-image-99\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p>&nbsp;Durasens&#x2122; LT-B Series Liquid Transmission Flow Cells are reliable, field tested basic cells suitable for analyzing liquid streams using transmission spectroscopy.<\/p>\n\n\n\n<p>The LT-B Series cells are available with round clear apertures of 8mm (Model LT-B13) and 20mm (Model LT-B25). Both models are available in temperature controlled versions (Models LT-B13-T and LT-B25-T).<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-4 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h4 class=\"alignwide has-accent-color has-text-color wp-block-heading\"><span style=\"color:#e15814\" class=\"has-inline-color\">LT-HP Series<br>High Pressure Liquid Transmission Flow Cells<br>Models LT-HP13, LT-HP13-T<\/span><\/h4>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-3 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"207\" height=\"235\" src=\"https:\/\/durasens.com\/wp-content\/uploads\/2021\/03\/LT-HP-web-3.jpg\" alt=\"\" class=\"wp-image-97\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p>Durasens&#x2122; LT-HP Series High Pressure Liquid Transmission Flow Cells are constructed from corrosion resistant 316 stainless steel and fitted with thick 13x6mm windows making them suitable for the analysis of liquid streams at high temperatures and pressures up to 5000 psi.<\/p>\n\n\n\n<p>The LT-HP Series cells have round clear apertures of 8mm. A&nbsp; variety of window materials is available. A temperature controlled version (Model LT-HP13-T) is also available.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-5 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n\n\n\n<h4 class=\"has-text-color wp-block-heading\" style=\"color:#e15814\"><strong><span style=\"color:#e15814\" class=\"has-inline-color\">LT-D Series<br>Diamond Liquid Transmission Cells<br>Models LT-D, LT-D-T, LT-D-P, LT-D-P-T<\/span><\/strong><\/h4>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-6 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"172\" height=\"238\" src=\"https:\/\/durasens.com\/wp-content\/uploads\/2021\/03\/LT-D-web-1.png\" alt=\"\" class=\"wp-image-95\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p>Durasens&#x2122;&nbsp;LT-D Series Diamond Liquid Transmission Cells are reliable, field tested cells suitable for analyzing liquid streams using transmission spectroscopy. Diamond windows provide spectral range from UV to Far IR, mechanical strength, chemical inertness and superior abrasion resistance.<\/p>\n\n\n\n<p>The LT-D Series cells have 7mm round clear aperture and are available in a temperature controlled version (Model LT-D-T ). The unsurpassed thermal conductivity of diamond provides superior control of sample temperature. A high pressure version (Models LT-D-P, LT-D-P-T) for operation up to 1000 psi is also available.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong><span style=\"color:#e15814\" class=\"has-inline-color\">LT-R Series<br>Rapid Flow Liquid Transmission Cells<br>Models LT-R13, LT-R13-F, LT-R13-T, LT-R13-F-T<\/span><\/strong><\/h4>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"215\" height=\"238\" src=\"https:\/\/durasens.com\/wp-content\/uploads\/2021\/03\/LT-R-web-1.png\" alt=\"\" class=\"wp-image-94\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p>Durasens&#x2122;&nbsp;LT-R Series Rapid Flow Liquid Transmission Cells are designed to monitor liquid streams in process environments using transmission spectroscopy.&nbsp; The patented (U.S. Patent 7,961,310) design of the cells allows for the high unimpeded flow of sample thus ensuring that the sample analyzed in the cell is the timely representation of the sample in the process line or reaction vessel. The rapid flow design also ensures that the cell does not get clogged by particulates in the process stream.<\/p>\n\n\n\n<p>The LT-R Series cells can be mounted directly in the sample compartment (Model LT-R13) or coupled to spectrometers with fiber optics (Model LT-R13-F). Both models are available in a temperature controlled version.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong><span style=\"color:#e15814\" class=\"has-inline-color\">LR-S Series<br>Single Reflection ATR Flow Through Liquid Cells<br>Models LR-S, LR-S-T<\/span><\/strong><\/h4>\n\n<div class=\"wp-block-column\" style=\"flex-basis:66.66%\">\n<p>Durasens&#x2122; LR-SR Single Reflection ATR Flow Through Liquid Cells are designed for monitoring process steams of liquids that strongly absorb infrared radiation. The types of liquid streams that could be monitored include a broad range of water based solutions. These cells are constructed of 316 stainless steel and have 1\/8\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\"><!-- wp:paragraph -->\n<p>Durasens&#x2122; LR-SR Single Reflection ATR Flow Through Liquid Cells are designed for monitoring process steams of liquids that strongly absorb infrared radiation. The types of liquid streams that could be monitored include a broad range of water based solutions. These cells are constructed of 316 stainless steel and have 1\/8\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-10 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"261\" height=\"237\" src=\"https:\/\/durasens.com\/wp-content\/uploads\/2021\/03\/LR-S-T-3web.jpg\" alt=\"\" class=\"wp-image-93\"\/><\/figure>\n<\/div>\n\n\n<!-- wp:column {\"width\":\"66.66%\"} -->\n<div class=\"wp-block-column\" style=\"flex-basis:66.66%\"><!-- wp:paragraph -->\n<p>Durasens&#x2122; LR-SR Single Reflection ATR Flow Through Liquid Cells are designed for monitoring process steams of liquids that strongly absorb infrared radiation. The types of liquid streams that could be monitored include a broad range of water based solutions. These cells are constructed of 316 stainless steel and have 1\/8","protected":false},"excerpt":{"rendered":"<p>Our broad range of robust liquid flow cells are equally at home in the laboratory, pilot plant or manufacturing plant. Constructed in a variety of materials such as various grades of stainless steel or Hastelloy, the cells can be customized depending on the spectral range and application. A variety of seals and any standard industrial [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-59","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/durasens.com\/index.php\/wp-json\/wp\/v2\/pages\/59","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/durasens.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/durasens.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/durasens.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/durasens.com\/index.php\/wp-json\/wp\/v2\/comments?post=59"}],"version-history":[{"count":10,"href":"https:\/\/durasens.com\/index.php\/wp-json\/wp\/v2\/pages\/59\/revisions"}],"predecessor-version":[{"id":122,"href":"https:\/\/durasens.com\/index.php\/wp-json\/wp\/v2\/pages\/59\/revisions\/122"}],"wp:attachment":[{"href":"https:\/\/durasens.com\/index.php\/wp-json\/wp\/v2\/media?parent=59"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}